
The Library
Do different mattresses affect the quality of cardiopulmonary resuscitation?
Tools
Perkins, Gavin D., Benny, Robert, Giles, Simon, Gao, Fang and Tweed, Michael J. (2003) Do different mattresses affect the quality of cardiopulmonary resuscitation? Intensive Care Medicine, 29 (12). pp. 2330-2335. doi:10.1007/s00134-003-2014-6 ISSN 0342-4642.
Research output not available from this repository.
Request-a-Copy directly from author or use local Library Get it For Me service.
Official URL: http://dx.doi.org/10.1007/s00134-003-2014-6
Abstract
Objective. To determine the effect of different mattresses on cardiopulmonary resuscitation performance and establish whether emergency deflation of an inflatable mattress improves the quality of resuscitation. Design and setting. Randomised controlled cross-over trial performed in a general ICU Participants. Critical care staff from a general ICU. Interventions. Cardiopulmonary resuscitation on a manikin on the floor or on a bed with a standard foam mattress and inflated and deflated pressure redistributing mattresses. Maximal compression force was measured at different bed heights. Measurements and results. Compression depth, duty cycle and rate and percentage correct expired air ventilation were recorded on a manikin. Compression depth was significantly lower on the foam (35.2 mm), inflated (37.2 mm) and deflated mattress (39.1 mm) than the floor (44.2 mm). There were no clinically important differences in duty cycle or compression rate. The quality of ventilation was poor on all surfaces. Maximal compression force declined as bed height increased. Conclusions. Resuscitation performance is adversely affected when performed on a bed (irrespective of mattress type) compared to the floor. There were no differences between the inflated and deflated mattresses, although the deflation process did not adversely affect performance. This study does not support the routine deflation of an inflated mattress during resuscitation and questions the potential benefits from using a backboard. The finding that bed height affects maximal compression forces, challenges the recommendation that cardiopulmonary resuscitation be performed with the bed at middle-thigh level and requires further investigation.
Item Type: | Journal Article | ||||||
---|---|---|---|---|---|---|---|
Subjects: | R Medicine > R Medicine (General) | ||||||
Divisions: | Faculty of Science, Engineering and Medicine > Medicine > Warwick Medical School > Clinical Trials Unit Faculty of Science, Engineering and Medicine > Medicine > Warwick Medical School > Health Sciences Faculty of Science, Engineering and Medicine > Medicine > Warwick Medical School |
||||||
Journal or Publication Title: | Intensive Care Medicine | ||||||
Publisher: | Springer International Publishing | ||||||
ISSN: | 0342-4642 | ||||||
Official Date: | December 2003 | ||||||
Dates: |
|
||||||
Volume: | 29 | ||||||
Number: | 12 | ||||||
Page Range: | pp. 2330-2335 | ||||||
DOI: | 10.1007/s00134-003-2014-6 | ||||||
Status: | Peer Reviewed | ||||||
Publication Status: | Published | ||||||
Access rights to Published version: | Restricted or Subscription Access |
Request changes or add full text files to a record
Repository staff actions (login required)
![]() |
View Item |