
The Library
Amphiphilic copolymers grafted on monodisperse magnetic microspheres as an efficient adsorbent for the extraction of safrole in the plasma
Tools
Nie, Ying, Luo, Yuan, Luo, Shajie, Cao, Xiujun, Song, Guoxin and Deng, Chunhui (2022) Amphiphilic copolymers grafted on monodisperse magnetic microspheres as an efficient adsorbent for the extraction of safrole in the plasma. Journal of Chromatography A, 1662 . 462733. doi:10.1016/j.chroma.2021.462733 ISSN 1873-3778.
Research output not available from this repository.
Request-a-Copy directly from author or use local Library Get it For Me service.
Official URL: https://doi.org/10.1016/j.chroma.2021.462733
Abstract
Polystyrene (PS) microsphere is a kind of attractive extracting medium due to its high stability in different matrices and its particle size can be controlled. The attachment of amphiphilic copolymers to the PS microsphere surface can overcome the drawback of PS relevant to its hydrophobic nature and low wettability. In our previous work, the magnetic composite based on PS microsphere (5 µm) and poly (divinylbenzene-co-N-vinylpyrrolidone, DVB-co-NVP) shell was successfully fabricated and applied for the extraction of safrole in cola drinks. However, the large size and ease of sedimentation limited its application in the enrichment of safrole from blood samples. Considering the adjustability of PS microsphere size, we synthesized the porous PS microspheres with the uniform size of 3 µm and then functionalized with Fe O nanoparticles and poly (DVB-co-NVP) layer in this work. Using the proposed material as extraction sorbent, a simple and fast magnetic solid phase extraction (MSPE) method coupled with HPLC was developed for quantification of safrole in the plasma. Under the optimized conditions, the response to safrole was linear in the range of 0.02-12 µg mL , and the limit of detection (LOD) was 0.006 µg mL . Satisfactory recoveries were obtained between 85.67% and 97.74% (spiked at 0.05, 0.2, 2 µg mL ) and the relative standard deviations (RSDs) for the above spiked levels of the analyte were below 3.9% (n = 6). The adsorbent can be reused for 6 cycles without a significant loss of extraction capability.
Item Type: | Journal Article | ||||||||
---|---|---|---|---|---|---|---|---|---|
Divisions: | Faculty of Science, Engineering and Medicine > Science > Physics | ||||||||
SWORD Depositor: | Library Publications Router | ||||||||
Journal or Publication Title: | Journal of Chromatography A | ||||||||
Publisher: | Elsevier | ||||||||
ISSN: | 1873-3778 | ||||||||
Official Date: | 11 January 2022 | ||||||||
Dates: |
|
||||||||
Volume: | 1662 | ||||||||
Article Number: | 462733 | ||||||||
DOI: | 10.1016/j.chroma.2021.462733 | ||||||||
Status: | Peer Reviewed | ||||||||
Publication Status: | Published | ||||||||
Access rights to Published version: | Restricted or Subscription Access |
Request changes or add full text files to a record
Repository staff actions (login required)
![]() |
View Item |