Serial lung function variability using four portable logging meters
Tools
Moore, Vicky C., Parsons, Nicholas R., Jaakkola, Maritta S., Burge, Cedd B.S.G., Pantin, Charles F., Robertson, Alastair S. and Burge, P. Sherwood (2009) Serial lung function variability using four portable logging meters. Journal of Asthma, Vol.46 (No.9). pp. 961-966. doi:10.3109/02770900903229677 ISSN 0277-0903.
Research output not available from this repository.
Request-a-Copy directly from author or use local Library Get it For Me service.
Official URL: http://dx.doi.org/10.3109/02770900903229677
Abstract
Objective. Portable lung function logging meters that allow measurement of peak expiratory flow (PEF) and forced expiratory volume in 1 second (FEV1) are useful for the diagnosis and exclusion of asthma. The aim of this study was to investigate the within and between-session variability of PEF and FEV1 for four logging meters and to determine the sensitivity of meters to detect FEV1 and PEF diurnal changes. Methods. Thirteen assessors (all hospital staff members) were asked to record 1 week of 2-hour PEF and FEV1 measurements using four portable lung function meters. Within-session variability of PEF and FEV1 were compared for each meter using a coefficient of variation (COV). Between-session variability was quantified using parameter estimates from a cosinor analysis which modeled diurnal change for both lung function measures and also allowed for variation between days for individual sessions. Results. The mean within-session COV for FEV1 was consistently lower than that for PEF (p < 0.001). PEF showed a higher but not significantly different (p = 0.068) sensitivity for detecting diurnal variation than FEV1. PEF was also slightly more variable between days, but not significantly different than FEV1 (p = 0.409). PEF and FEV1 diurnal variability did not differ between the 4 meters (p = 0.154 and 0.882 respectively), but within-session FEV1 COV differed between meters (p = 0.009). Conclusion. PEF was marginally more sensitive to within-day variability than FEV1 but was less repeatable. Overall, differences between the 4 meters were small, suggesting that all meters are clinically useful.
Item Type: | Journal Article | ||||
---|---|---|---|---|---|
Subjects: | R Medicine > RC Internal medicine | ||||
Divisions: | Faculty of Science, Engineering and Medicine > Medicine > Warwick Medical School > Health Sciences Faculty of Science, Engineering and Medicine > Medicine > Warwick Medical School |
||||
Library of Congress Subject Headings (LCSH): | Pulmonary function tests, Respiration -- Measurement, Asthma | ||||
Journal or Publication Title: | Journal of Asthma | ||||
Publisher: | Informa Healthcare | ||||
ISSN: | 0277-0903 | ||||
Official Date: | November 2009 | ||||
Dates: |
|
||||
Volume: | Vol.46 | ||||
Number: | No.9 | ||||
Page Range: | pp. 961-966 | ||||
DOI: | 10.3109/02770900903229677 | ||||
Status: | Peer Reviewed | ||||
Publication Status: | Published | ||||
Access rights to Published version: | Restricted or Subscription Access |
Data sourced from Thomson Reuters' Web of Knowledge
Request changes or add full text files to a record
Repository staff actions (login required)
View Item |