A short version of the International Hip Outcome Tool (iHOT-12) for use in routine clinical practice

Tools
- Tools
+ Tools

Griffin, Damian R., Parsons, Nicholas R., Mohtadi, Nicholas G. H. and Safran, Marc R. (2012) A short version of the International Hip Outcome Tool (iHOT-12) for use in routine clinical practice. Arthroscopy: The Journal of Arthroscopic & Related Surgery, Vol.28 (No.5). pp. 611-618. doi:10.1016/j.arthro.2012.02.027 ISSN 0749-8063.

Research output not available from this repository.

Request-a-Copy directly from author or use local Library Get it For Me service.

Official URL: http://dx.doi.org/10.1016/j.arthro.2012.02.027

Request Changes to record.

Abstract

Purpose
The purpose of this study was to develop and validate a shorter version of the 33-item International Hip Outcome Tool (iHOT-33) that could be easily used in routine clinical practice to measure both health-related quality of life and changes after treatment in young, active patients with hip disorders.

Methods
A development dataset (104 patients) was explored with forward-selection linear regression analysis to choose a reduced item set for the new scale. This was tested in a validation dataset (1,833 patients) and responsiveness subset (80 patients) to measure agreement between the shorter and longer versions and to test the sensitivity of the shorter instrument to change after treatment.

Results
Twelve items were chosen for a short version of the International Hip Outcome Tool (iHOT-12). The iHOT-12 showed excellent agreement with the long version (iHOT-33). It captured 95.9% (95% confidence interval, 95.0% to 96.8%) of the variation of the iHOT-33 and showed equivalent sensitivity to change with a standardized effect size of 0.98 (95% confidence interval, 0.67 to 1.28).

Conclusions
A short version of the International Hip Outcome Tool (iHOT-12) has been developed. It has very similar characteristics to the original rigorously validated 33-item questionnaire, losing very little information despite being only one-third the length. It is valid, reliable, and responsive to change. We suggest that it be used for initial assessment and postoperative follow-up in routine clinical practice.

Item Type: Journal Article
Divisions: Faculty of Science, Engineering and Medicine > Medicine > Warwick Medical School
Journal or Publication Title: Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher: W.B. Saunders Co.
ISSN: 0749-8063
Official Date: 2012
Dates:
DateEvent
2012Published
Volume: Vol.28
Number: No.5
Page Range: pp. 611-618
DOI: 10.1016/j.arthro.2012.02.027
Status: Peer Reviewed
Publication Status: Published
Access rights to Published version: Restricted or Subscription Access