The Library
Roller compaction of moist pharmaceutical powders
Tools
Wu, C. -Y., Hung, W. -L., Miguelez-Moran, A. M., Gururajan, B. and Seville, J. P. K. (Jonathan P. K.) (2010) Roller compaction of moist pharmaceutical powders. International Journal of Pharmaceutics, Vol.391 (No.1-2). pp. 90-97. doi:10.1016/j.ijpharm.2010.02.022 ISSN 0378-5173.
Research output not available from this repository.
Request-a-Copy directly from author or use local Library Get it For Me service.
Official URL: http://dx.doi.org/10.1016/j.ijpharm.2010.02.022
Abstract
The compression behaviour of powders during roller compaction is dominated by a number of factors, such as process conditions (roll speed, roll gap, feeding mechanisms and feeding speed) and powder properties (particle size, shape, moisture content). The moisture content affects the powder properties, such as the flowability and cohesion, but it is not clear how the moisture content will influence the powder compression behaviour during roller compaction. In this study, the effect of moisture contents on roller compaction behaviour of microcrystalline cellulose (MCC, Avicel PHI 02) was investigated experimentally. MCC samples of different moisture contents were prepared by mixing as-received MCC powder with different amount of water that was sprayed onto the powder bed being agitated in a rotary mixer. The flowability of these samples were evaluated in terms of the poured angle of repose and flow functions. The moist powders were then compacted using the instrumented roller compactor developed at the University of Birmingham. The flow and compression behaviour during roller compaction and the properties of produced ribbons were examined. It has been found that, as the moisture content increases, the flowability of moist MCC powders decreases and the powder becomes more cohesive. As a consequence of non-uniform flow of powder into the compaction zone induced by the friction between powder and side cheek plates, all produced ribbons have a higher density in the middle and lower densities at the edges. For the ribbons made of powders with high moisture contents, different hydration states across the ribbon width were also identified from SEM images. Moreover, it was interesting to find that these ribbons were split into two halves. This is attributed to the reduction in the mechanical strength of moist powder compacts with high moisture contents produced at high compression pressures. (C) 2010 Elsevier B.V. All rights reserved.
Item Type: | Journal Article | ||||
---|---|---|---|---|---|
Subjects: | R Medicine > RS Pharmacy and materia medica | ||||
Divisions: | Faculty of Science, Engineering and Medicine > Engineering > Engineering | ||||
Journal or Publication Title: | International Journal of Pharmaceutics | ||||
Publisher: | Elsevier Science BV | ||||
ISSN: | 0378-5173 | ||||
Official Date: | 31 May 2010 | ||||
Dates: |
|
||||
Volume: | Vol.391 | ||||
Number: | No.1-2 | ||||
Number of Pages: | 8 | ||||
Page Range: | pp. 90-97 | ||||
DOI: | 10.1016/j.ijpharm.2010.02.022 | ||||
Status: | Peer Reviewed | ||||
Publication Status: | Published | ||||
Access rights to Published version: | Restricted or Subscription Access | ||||
Funder: | Engineering and Physical Sciences Research Council (EPSRC) | ||||
Grant number: | EP/C545230 (EPSRC), EP/C545249 (EPSRC) |