Alavi, Shiva, Barooti, Sara and Borzabadi-Farahani, Ali (2015) An in vitro assessment of the mechanical characteristics of nickel-titanium orthodontic wires in Fluoride solutions with different acidities. Journal of Orthodontic Science, Volume 4 (Number 2). pp. 52-56. doi:10.4103/2278-0203.156030 ISSN 2278-0203.
|
PDF
WRAP_4026299-md-010515-f_and_niti (1).pdf - Published Version - Requires a PDF viewer. Available under License Creative Commons Attribution Non-commercial Share Alike. Download (854Kb) | Preview |
Official URL: http://dx.doi.org/10.4103/2278-0203.156030
Abstract
Objectives:
The aim was to evaluate the in vitro effects of fluoride solutions with different acidities on load-deflection characteristics of nickel-titanium (NiTi) orthodontic wires.
Materials and Methods:
In this study, which lasted 30 days, 36 (3 cm long, 0.016 × 0.022 inches, SENT 1622, G & H wire Company, Greenwood, Indiana, USA) NiTi wires, were divided into three experimental groups of 12 each. Two groups were subjected to 0.05 topical fluoride mouthwash with different acidities (G1, pH 4; G2, pH 6.6) for 90 s, twice a day, and kept in normal saline after that. The third group (G3, the control group) was kept in normal saline only. Load and unload forces were measured with three bracket bending test in a universal testing machine (Testometric Co, Rochdale, UK). Loading and unloading plateaus and hysteresis were also recorded. Data were then analyzed using analysis of variance and honestly significant difference Tukey at P < 0.05.
Results:
During the loading phase, there was a significant difference between deflections (P < 0.001); but there was no interaction effect (P = 0.191) and no significant difference among three groups (P = 0.268). In the unloading phase, there was a significant difference between deflections (P < 0.001) and an interaction effect was also observed (P = 0.008). Further, significant differences noted among three groups (P = 0.037). Only in the unloading phase, at deflections of 2.2 through 0.2 mm, significant differences between the mean force values of the G1 and G3 groups were observed (P = 0.037).
Conclusion:
Based on this in-vitro study, compared to neutral fluoride solution, daily mouthwash with a fluoride solution with more acidic pH of 4 affected the NiTi wires load-deflection characteristics during the unloading phase. This finding may have clinical implications and can be further validated by in-vivo studies.
Item Type: | Journal Article | ||||
---|---|---|---|---|---|
Subjects: | R Medicine > RK Dentistry | ||||
Divisions: | Faculty of Science, Engineering and Medicine > Medicine > Warwick Medical School > ( - July 2016) Health Education Hub Faculty of Science, Engineering and Medicine > Medicine > Warwick Medical School |
||||
Library of Congress Subject Headings (LCSH): | Orthodontic appliances, Nickel-titanium alloys -- Mechanical properties, Mouthwashes | ||||
Journal or Publication Title: | Journal of Orthodontic Science | ||||
Publisher: | Medknow | ||||
ISSN: | 2278-0203 | ||||
Official Date: | 29 April 2015 | ||||
Dates: |
|
||||
Volume: | Volume 4 | ||||
Number: | Number 2 | ||||
Number of Pages: | 5 | ||||
Page Range: | pp. 52-56 | ||||
DOI: | 10.4103/2278-0203.156030 | ||||
Status: | Peer Reviewed | ||||
Publication Status: | Published | ||||
Access rights to Published version: | Restricted or Subscription Access | ||||
Date of first compliant deposit: | 28 July 2016 | ||||
Date of first compliant Open Access: | 28 July 2016 |